G-Tek® VR-X™

Seamless Knit Nylon Glove with Polyurethane Advanced Barrier Protection Coating on Full Hand – Touchscreen Compatible

33-VRX180

3111

EN 388 2016 Results: 3111XX
Abrasion: 3
Cut (Coupe Test): 1
Tear: 1
Puncture: 1
Cut (TDM-100 Test): X
Impact Protection: X

EN 388 is a European Standard. Cut Level is determined by the number of cycles it takes a spinning circular blade, that is pulled across the material under a constant weight of 500 grams, to cut the fabric. As the number of cycles increase, so does the glove's ratings. Click here for more information about the EN 388 2016 standard.

ANSI Puncture Level: 2
Test Method: ASTM F1342

The ANSI/ISEA 105-2016 blunt force puncture testing uses a probe to simulate a tear or burst hazard. The test measures the amount of force needed for a blunt probe to pierce through PPE material. Results are given in Newtons, which is converted into a 1-5 scale and spans from 10 newtons (Level 1) to 150+ newtons (Level 5) of puncture resistance.

Protective Gloves Against Micro-organisms

The EN ISO 374-5 VIRUS standard measures the ability of gloves to protect users against bacteria, fungi and viruses. Gloves with this marking must pass EN374-2 for leak testing.

Extended Life - Reusable/Launderable

Reusing or laundering products not only reduces cost, but also reduces the amount of waste that is put into our landfills in turn reducing the environmental impact.

ESD Safe

ESD is an acronym for electrostatic discharge. This discharge is the rapid transfer of static between two different objects. Although ESD doesn’t typically cause harm to the human body - you might only experience it as a small, surprising shock - it can cause extensive damage to electrical equipment and sensitive instruments. This damage may either be permanent, causing the device to malfunction (known as a catastrophic failure), or it may occur on a smaller scale that would be difficult to detect before the device is sent out for service (known as latent defect).

FENTANYL PROTECTION
Test Method: ASTM D6978-05

In accordance with ASTM D6978-05, Personal Protective Equipment can be tested to ensure an effective barrier against Fentanyl. The ASTM D6978-05 Standard Practice for Assessment of Medical Gloves to Permeation by Chemotherapy Drug tests a breakthrough time of typically 240 minutes to determine if the PPE provides an effective barrier.

Touchscreen Compatible

A common misconception is that touchscreens work based on heat from fingers. It's not heat that generates touchscreen functionality, instead, most screens work either on finger pressure applied or electrical field disruption. Basically, this means there are two main types of touchscreen technologies, Resistive and Capacitive.

Click here for more information about Resistive and Capacitive Touchscreens

Available Colors:

Black
  • SIZES: XS-XXL
  • Packed: 12 Dozen/Case
  • Country of Origin: China
Product Attributes

Liner Material: Nylon

Nylon: Seamless nylon liner offers increased comfort, finger dexterity and breathability.

View All Nylon

Coating: Polyurethane

Polyurethane: Polyurethane (PU) is a tough, proven material that offers good tactile sensitivity by way of its thin material deposit. It conforms intimately over multiple glove liners to provide flexibility, dexterity and tactile sensitivity. PU coated gloves are among the most commonly used because they are versatile and provide excellent value. Newer, water-based PU coatings offer improved flexibility and less environmental lifecycle impact.

View All Polyurethane

Grip: Foam

Foam: Available in Nitrile, NeoFoam® and PVC, foam coating cell structure is designed to channel fluids away from the surface of the object helping improve grip in slightly oily/wet conditions. Secure grip in dry conditions. Oily/wet grip varies with density of cell structure.

View All Foam
Product Description

Product Description

Ideal for handling and assembly of small to medium sharp parts and materials, manufacturing, inspection, shipping and packaging and mechanical equipment maintenance and repair.

Features

  • Seamless construction offers increased comfort and breathability
  • Nylon blended shell, featuring an ultra-thin 18 gauge liner for exceptional dexterity
  • VR-X Polyurethane coatings provide advanced barrier protection, the treated coating takes on the surface properties of the glove liner providing a tactile grip in wet, dry and slightly oily conditions, ideal for applications that require dexterity for precise handling
  • Liquid proof, air leak tested - EN374-2
  • Antibacterial and antiviral barrier protection per ISO 20743:2013 test method & EN374-5
  • ESD Safe, Surface Resistance per ESD S11.11 Static dissipative range at 10^8 ohms, 12%RH, 48hrs @100Volts
  • 4.0 AQL, similar to the AQL levels for industrial grade disposable gloves
  • Touchscreen compatible to allow the user to operate a touch screen phone or device without removing gloves
  • Silicone free
  • Knit Wrist helps prevent dirt and debris from entering the glove
  • Color coded hems for easy size identification
  • Washable, resistant to water and ultraviolet light
  • Recommended wash cycle: maximum 6 cycles

Related Product Downloads

  • Seamless Knit
  • Blue 18G Nylon Shell
  • Black Full Dip VR-X PU Coating
  • Liquid Proof
  • AQL 4.0
  • Touchscreen
  • Silicone Free
  • ESD Safe
  • Pair Bagged
Product Videos
Standards Met

EN 388 2016 Results: 3111XX

Abrasion: 3 Cut (Coupe Test): 1 Tear: 1 Puncture: 1 Cut (TDM-100 Test): X Impact Protection: X

EN 388 is a European Standard. Cut Level is determined by the number of cycles it takes a spinning circular blade, that is pulled across the material under a constant weight of 500 grams, to cut the fabric. As the number of cycles increase, so does the glove's ratings. Click here for more information about the EN 388 2016 standard.

ANSI Puncture Level: 2

Test Method: ASTM F1342

The ANSI/ISEA 105-2016 blunt force puncture testing uses a probe to simulate a tear or burst hazard. The test measures the amount of force needed for a blunt probe to pierce through PPE material. Results are given in Newtons, which is converted into a 1-5 scale and spans from 10 newtons (Level 1) to 150+ newtons (Level 5) of puncture resistance.

Protective Gloves Against Micro-organisms Bacteria, Fungi and Virus

The EN ISO 374-5 VIRUS standard measures the ability of gloves to protect users against bacteria, fungi and viruses. Gloves with this marking must pass EN374-2 for leak testing.

Extended Life - Reusable/Launderable

Reusing or laundering products not only reduces cost, but also reduces the amount of waste that is put into our landfills in turn reducing the environmental impact.

FENTANYL PROTECTION

Test Method: ASTM D6978-05

In accordance with ASTM D6978-05, Personal Protective Equipment can be tested to ensure an effective barrier against Fentanyl. The ASTM D6978-05 Standard Practice for Assessment of Medical Gloves to Permeation by Chemotherapy Drug tests a breakthrough time of typically 240 minutes to determine if the PPE provides an effective barrier.

The G-Tek® brand is applied to seamless knit coated gloves used for various cut protection and general purpose applications for various industrial, construction, and MRO applications. As a comprehensive line of hand protection, G-Tek® encompasses several technology platforms to meet the various needs of the market. Each cut resistant glove is tested to both ANSI and EN standards, and test scores are readily available on each product’s webpage.

View Products
Compare ()
Clear All Compare
Okay, Got it.
X

ORDER SAMPLE

X

GET FIELD TRIAL