Kut Gard®

ATA®/ HPPE Blended Sleeve

20-S13ATA/PE3

ansi-A3
ANSI Cut Level: A3
Test Method: ASTM F2992-15

New edition ANSI/ISEA 105-2016 outlines a new test method for determining cut scores and a revised scale from A1-A9. Click here for more information about the new testing standard.

ansi-abrasion-3
ANSI Abrasion Level: 3
Test Method: ASTM D3884-09

The ANSI/ISEA 105-2016 standard outlines test methods for abrasion and is scored from 0-6. The ASTM D3884-09 is used for uncoated gloves and the end point (failure) is the number of abrasion cycles when the first thread or yarn is broken. The larger numbers of cycles indicates greater abrasion resistance of the product and a higher ANSI Abrasion Level.

ANSI Puncture Level: 3
Test Method: ASTM F1342

The ANSI/ISEA 105-2016 blunt force puncture testing uses a probe to simulate a tear or burst hazard. The test measures the amount of force needed for a blunt probe to pierce through PPE material. Results are given in Newtons, which is converted into a 1-5 scale and spans from 10 newtons (Level 1) to 150+ newtons (Level 5) of puncture resistance.

Extended Life - Reusable/Launderable

Reusing or laundering products not only reduces cost, but also reduces the amount of waste that is put into our landfills in turn reducing the environmental impact.

Available Colors:

Gray
  • SIZES: 18"
  • Packed: 144/Case
  • Country of Origin: United States
Product Attributes

Liner Material: ATA Fiber Technology / HPPE

ATA Fiber Technology: ATA® Fiber Technology cut resistant gloves and sleeves offer ANSI cut protection from A2 through A9 and can be blended with both HPPE, for breathability and comfort, or Aramid for heat resistance.
HPPE: Products constructed with High Performance Polyethylene Fiber (HPPE) fibers are suitable for protection against mechanical hazards in the toughest environments. HPPE fiber products can be designed for different protection levels, up to the highest levels, while maintaining an unprecedented level of comfort. They are also highly resistant to abrasion and chemicals, so you can rely on them to provide long-lasting protection.

View All ATA Fiber TechnologyView All HPPE

Construction: Machine Knit

Machine Knit:

View All Machine Knit

Top of Arm: Overstitched Elastic

Overstitched Elastic:

View All Overstitched Elastic
Product Description

Product Description

Antimicrobial sleeves featuring ATA® Technology; a cool wearing HPPE blend with excellent stretch and memory retention. Color coded hem identifies ANSI cut protection score so safety managers and workers can quickly confirm that they are wearing the appropriate cut protection for the application.

Features

  • Proprietary ATA® Technology with HPPE fiber blend provides ANSI A3 cut protection and outstanding wearer comfort
  • Lightweight 13 gauge HPPE fiber blend is cool wearing and is more comfortable than other engineered fibers
  • Color-coded overedge indicates cut protection, orange indicates ANSI A3, for visual confirmation and worker safety
  • Antimicrobial fiber helps to prevent bacterial growth
  • Knit wrist stays in place and is less binding than elastic wrist
  • Good washability can be washed in soap and water or dry cleaned
  • Available with or without thumb-hole
  • Made in the USA
  • ATA
  • HPPE
  • 13G Knit
  • A3
  • Gray
  • 18"
Standards Met

ANSI Cut Level: A3

ansi-A3

Test Method: ASTM F2992-15

New edition ANSI/ISEA 105-2016 outlines a new test method for determining cut scores and a revised scale from A1-A9. Click here for more information about the new testing standard.

ANSI Abrasion Level: 3

ansi-abrasion-3

Test Method: ASTM D3884-09

The ANSI/ISEA 105-2016 standard outlines test methods for abrasion and is scored from 0-6. The ASTM D3884-09 is used for uncoated gloves and the end point (failure) is the number of abrasion cycles when the first thread or yarn is broken. The larger numbers of cycles indicates greater abrasion resistance of the product and a higher ANSI Abrasion Level.

ANSI Puncture Level: 3

Test Method: ASTM F1342

The ANSI/ISEA 105-2016 blunt force puncture testing uses a probe to simulate a tear or burst hazard. The test measures the amount of force needed for a blunt probe to pierce through PPE material. Results are given in Newtons, which is converted into a 1-5 scale and spans from 10 newtons (Level 1) to 150+ newtons (Level 5) of puncture resistance.

Extended Life - Reusable/Launderable

Reusing or laundering products not only reduces cost, but also reduces the amount of waste that is put into our landfills in turn reducing the environmental impact.

Made in the U.S.A., Kut Gard® seamless knit gloves and sleeves are designed to provide the highest possible cut protection for the food industry. Because they comply with both the US and Canadian standards for food contact, Kut Gard® gloves and sleeves blended with antimicrobial fibers can be used for operations where direct, indirect, and incidental contact with food may occur.

View Products
Compare ()
Clear All Compare
Okay, Got it.
X

ORDER SAMPLE

X

GET FIELD TRIAL